Daily: temperatures and doors
Record cabinet and cold room temperatures at opening and again mid-service. Look at the door seals as you close them, and make sure nothing is stored in front of a condenser grille or an evaporator fan. Most early warnings are visible to whoever opens up.
Weekly: airflow and drains
Pull units out far enough to clear dust and flour from condenser coils, check that cold room drains run free, and confirm nothing has been stacked against the evaporator. A blocked drain becomes an ice block, and an iced evaporator becomes a warm room by Friday.
Quarterly: the professional visit
A technician should clean coils properly, verify temperatures against a calibrated probe, check door heaters and gaskets, observe a full defrost cycle and test compressor current. You should get a written note of what is wearing out. If you only get an invoice, ask for the report.
In short
- Two temperature readings a day catch most failures early.
- Never store stock against a coil, fan or drain.
- Insist on a written condition report per visit.